Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients.

Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, Hamasaki N, Horiuchi H, Ohishi H.

Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.

To further understand the temporal mode and mechanisms of coronary restenosis, 229 patients were studied by prospective angiographic follow-up on day 1 and at 1, 3 and 6 months and 1 year after successful percutaneous transluminal coronary angioplasty. Quantitative measurement of coronary stenosis was achieved by cinevideodensitometric analysis. Actuarial restenosis rate was 12.7% at 1 month, 43.0% at 3 months, 49.4% at 6 months and 52.5% at 1 year. In 219 patients followed up for greater than or equal to 3 months, mean stenosis diameter was 1.91 +/- 0.53 mm immediately after coronary angioplasty, 1.72 +/- 0.52 mm on day 1, 1.86 +/- 0.58 mm at 1 month and 1.43 +/- 0.67 mm at 3 months. In 149 patients followed up for greater than or equal to 6 months, mean stenosis diameter was 1.66 +/- 0.58 mm at 3 months and 1.66 +/- 0.62 mm at 6 months. In 73 patients followed up for 1 year, mean stenosis diameter was 1.65 +/- 0.56 mm at 6 months and 1.66 +/- 0.57 mm at 1 year. Thus, stenosis diameter decreased markedly between 1 month and 3 months after coronary angioplasty and reached a plateau thereafter. In conclusion, restenosis is most prevalent between 1 and 3 months and rarely occurs beyond 3 months after coronary angioplasty.

PMID: 2969925 [PubMed - indexed for MEDLINE]